DETAILS
The Excalibur screw bolt with Hex head is very versatile with a simple and fast installation process.
Giving a close to the edge ability due to its non expanding design, it provides exceptional strength and immediate load capacity in many substrates.
- Available in various diameters for all projects, giving a cost effective solution
- Suitable for scaffold, formwork and many other applications
- The Excalibur Screwbolt is the market leader in construction fixings
HSB 10MM OPTIONSScrewbolt Diameter | Head Details and Diameter | Clearance Hole Diameter | Max Fixing Thickness ‘A’ | Thread Length ‘B’ | Clearance Depth ‘C’ | Box Quantity | Order code: |
---|
10mm | 17mm Hex. Drive Flange Diameter 22mm | 12mm | 15mm | 60mm | 20mm | 50 | HSB 10 / 060 |
10mm | 12mm | 30mm | 75mm | 20mm | 50 | HSB 10 / 075 |
10mm | 12mm | 50mm | 100mm | 20mm | 50 | HSB 10 / 100 |
10mm | 12mm | 70mm | 120mm | 20mm | 50 | HSB 10 / 120 |
10mm | 12mm | 100mm | 150mm | 20mm | 50 | HSB 10/ 150 |
Drill Bit Diameter | Concrete and Brick | 10.0mm |
Soft Materials | 9.0mm |
ULTIMATE & SAFE LOAD CHARACTERISTICS BASED ON 3:1 RATIOMaterial | Embedment Depth (mm) | Tensile Load kN. | Shear Load kN. | Max. Torque Nm. ** |
---|
Ultimate | Safe | Ultimate | Safe | – |
Concrete | 60 N/mm² | 50 | 29.00 | 9.67 | – | – | – |
60 N/mm² | 75 | 48.00 | 16.00 | 46.00 | 15.33 | – |
Concrete | 35 N/mm² | 50 | 18.80 | 6.27 | – | – | – |
35 N/mm² | 75 | 33.40 | 11.13 | 46.00 | 15.33 | – |
Engr. Brick | 100 N/mm² | 45 | 20.00 | 6.67 | – | – | – |
Semi.Engr. | 70 N/mm² | 45 | 14.20 | 4.73 | – | – | – |
Fletton | 20 N/mm² | 45 | 11.60 | 3.87 | – | – | – |
Butterly | 20 N/mm² | 45 | 3.90 | 1.30 | – | – | – |
Hemelite | 3.5 N/mm² | 75 | 10.60 | 3.53 | – | – | 15 |
Lignacite | 3.5 N/mm² | 75 | 9.00 | 3.00 | – | – | 15 |
Topcrete | 7.0 N/mm² | 75 | 14.00 | 4.67 | – | – | 15 |
**With softer materials, care should be taken not to exceed the maximum recommended torque, as this may result in the de-grading of the matrix.
HSB 10MM TECHNICAL DATAMaterial | Boron Steel BS3111/9/2.1.A |
---|
Finish | Zinc & Yellow passivated as standard, or mechanical zinc |
---|
Other finishes | Other platings & finishes are available to special order subject to quantity |
---|
Tensile strength | 800N/mm2 Case hardened |
---|
Other sizes | Other lengths of all diameters are available to special order subject to quantity |
---|
Embedment concrete and brick | Minimum recommended is 4.5 × bolt diameter |
---|
Soft block | Minimum recommended is 75mm |
---|
| |
---|
FOR EDGE AND SPACING DISTANCES MINIMUM 5 DIAMETER AND BETWEEN 5-10 DIAMETER SEE REDUCTION FACTORS
HSB 12MM OPTIONSScrewbolt Diameter | Head Details and Diameter | Clearance Hole Diameter | Max Fixing Thickness ‘A’ | Thread Length ‘B’ | Clearance Depth ‘C’ | Box Quantity | Order code: |
---|
12mm | 19mm Hex. Drive Flange dia. 25mm | 15mm | 20mm | 75mm | 24mm | 50 | HSB 12 / 075 |
12mm | 15mm | 46mm | 100mm | 24mm | 50 | HSB 12 / 100 |
12mm | 15mm | 96mm | 150mm | 24mm | 25 | HSB 12 / 150 |
Drill Bit Diameter | Concrete and Brick | 12.0mm |
Soft Materials | 11.0mm |
ULTIMATE & SAFE LOAD CHARACTERISTICS BASED ON 3:1 RATIOMaterial | Embedment Depth (mm) | Tensile Load kN. | Shear Load kN. | Max. Torque Nm. ** |
---|
Ultimate | Safe | Ultimate | Safe | – |
Concrete | 60 N/mm² | 60 | 38.70 | 12.90 | – | – | – |
60 N/mm² | 90 | 69.00 | 23.00 | 59.80 | 19.93 | – |
Concrete | 35 N/mm² | 60 | 26.50 | 8.83 | – | – | – |
35 N/mm² | 90 | 43.00 | 14.33 | 59.80 | 19.93 | – |
Engr. Brick | 100 N/mm² | 45 | 20.00 | 6.67 | – | – | – |
Semi.Engr. | 70 N/mm² | 45 | 15.00 | 5.00 | – | – | – |
Fletton | 20 N/mm² | 45 | 15.80 | 5.27 | – | – | – |
Butterly | 20 N/mm² | 45 | 5.10 | 1.70 | – | – | – |
Hemelite | 3.5 N/mm² | 75 | 12.10 | 4.03 | – | – | 15 |
Lignacite | 3.5 N/mm² | – | – | – | – | – | – |
Topcrete | 7.0 N/mm² | 75 | 18.90 | 6.30 | – | – | 15 |
**With softer materials, care should be taken not to exceed the maximum recommended torque, as this may result in the de-grading of the matrix.
HSB 12MM TECHNICAL DATAMaterial | Boron Steel BS3111/9/2.1.A |
---|
Finish | Zinc & Yellow passivated as standard, or mechanical zinc |
---|
Other finishes | Other platings & finishes are available to special order subject to quantity |
---|
Tensile strength | 800N/mm2 Case hardened |
---|
Other sizes | Other lengths of all diameters are available to special order subject to quantity |
---|
Embedment concrete and brick | Minimum recommended is 4.5 × bolt diameter |
---|
Soft block | Minimum recommended is 75mm |
---|
| |
---|
FOR EDGE AND SPACING DISTANCES MINIMUM 5 DIAMETER AND BETWEEN 5-10 DIAMETER SEE REDUCTION FACTORS
HSB 16MM OPTIONSScrewbolt Diameter | Head Details and Diameter | Clearance Hole Diameter | Max Fixing Thickness ‘A’ | Thread Length ‘B’ | Clearance Depth ‘C’ | Box Quantity | Order code: |
---|
16mm | 24mm Hex Drive. Flange Diameter 32mm | 19mm | 28mm | 100mm | 32mm | 25 | HSB 16 / 100 |
16mm | 19mm | 28mm | 120mm | 32mm | 25 | HSB 16 / 120 |
16mm | 19mm | 58mm | 150mm | 32mm | 25 | HSB 16 / 150 |
16mm | 19mm | 158mm | 200mm | 32mm | 25 | HSB 16 / 200 |
Drill Bit Diameter | Concrete | 16.0mm |
– | – |
HSB 16MM TECHNICAL DATAMaterial | Boron Steel BS3111/9/2.1.A |
---|
Finish | Zinc & Yellow passivated as standard, or mechanical zinc |
---|
Other finishes | Other platings & finishes are available to special order subject to quantity |
---|
Tensile strength | 800N/mm2 Case hardened |
---|
Other sizes | Other lengths of all diameters are available to special order subject to quantity |
---|
Embedment concrete and brick | Minimum recommended is 4.5 × bolt diameter |
---|
Soft block | Minimum recommended is 75mm |
---|
Design Tables based on ETAG Approval ETA (11/0259)
Table 1: Mean Ultimate resistance (Nru.m from test results) Anchor Size (mm) | 16 | 16 | 20 | 20 | 20 | 20 |
Hef nominal (mm) | 120 | 120 | 170 | 170 | 250 | 250 |
Non-Cracked Concrete | C20/25 | C50/60 | C20/25 | C50/60 | C20/25 | C50/60 |
Tensile Nru,m [kN] | 44.30 | 74.60 | 82.90 | 121.75 | 206.40 | 223.56 |
Shear Vru,m [kN] | 94.00 | 94.00 | 155.40 | 155.40 | 155.40 | 155.40 |
Cracked Concrete | C20/25 | C50/60 | C20/25 | C50/60 | C20/25 | C50/60 |
Tensile Nru,m [kN] | 31.80 | 43.84 | 44.60 | 79.37 | NT | NT |
Shear Vru,m [kN] | 94.00 | 94.00 | 155.40 | 155.40 | NT | NT |
Table 2: Characteristic resistance ( NRk = NRu.m (1-k5%V) Anchor Size (mm) | 16 | 16 | 20 | 20 | 20 | 20 |
Hef nominal (mm) | 120 | 120 | 170 | 170 | 250 | 250 |
Non-Cracked Concrete | C20/25 | C50/60 | C20/25 | C50/60 | C20/25 | C50/60 |
Tensile NRk [kN] | 32.30 | 54.30 | 40.60 | 92.77 | 143.70 | 171.18 |
Shear VRk [kN] | 91.70 | 91.70 | 139.50 | 139.50 | 139.50 | 139.50 |
Cracked Concrete | C20/25 | C50/60 | C20/25 | C50/60 | C20/25 | C50/60 |
Tensile NRk [kN] | 19.90 | 21.48 | 26.40 | 38.89 | NT | NT |
Shear VRk [kN] | 91.70 | 91.70 | 139.50 | 139.50 | NT | NT |
Table 3: Design Resistance (NRd = NRk/ym)Anchor Size (mm) | 16 | 16 | 20 | 20 | 20 | 20 |
Hef nominal (mm) | 120 | 120 | 170 | 170 | 250 | 250 |
Non-Cracked Concrete | C20/25 | C50/60 | C20/25 | C50/60 | C20/25 | C50/60 |
Tensile NRd [kN] | 17.90 | 30.16 | 22.60 | 51.53 | 79.90 | 95.10 |
Shear VRd [kN] | 73.30 | 73.30 | 111.60 | 111.60 | 111.60 | 111.60 |
Cracked Concrete | C20/25 | C50/60 | C20/25 | C50/60 | C20/25 | C50/60 |
Tensile NRd [kN] | 9.95 | 10.74 | 13.20 | 19.45 | NT | NT |
Shear VRd [kN] | 73.30 | 73.30 | 111.60 | 111.60 | NT | NT |
Table 4: Recommended Load (Nrec = NRd/y) Anchor Size (mm) | 16 | 16 | 20 | 20 | 20 | 20 |
Hef nominal (mm) | 120 | 120 | 170 | 170 | 250 | 250 |
Non-Cracked Concrete | C20/25 | C50/60 | C20/25 | C50/60 | C20/25 | C50/60 |
Tensile Nrec [kN] | 12.80 | 21.54 | 16.14 | 36.80 | 57.07 | 67.92 |
Shear Vrec [kN] | 52.40 | 52.40 | 79.70 | 79.70 | 79.70 | 79.70 |
Cracked Concrete | C20/25 | C50/60 | C20/25 | C50/60 | C20/25 | C50/60 |
Tensile Nrec [kN] | 7.10 | 7.70 | 9.40 | 13.90 | NT | NT |
Shear Vrec [kN] | 52.40 | 52.40 | 79.70 | 79.70 | NT | NT |
NT = Not Tested
Revised October 6th 2014 (shear values extended)
Minimum thickness of concrete member, minimum spacing and minimum edge distance for cracked and non-cracked concrete (without reduction factors) |
Anchor size (mm) | hnom120mm | hnom170mm |
16 | 20 |
Minimum thickness of member | 165mm | 220mm |
Minimum edge distance | 185mm | 180mm |
Minimum spacing | 240mm | 340mm |
Reduction Factors for Edge distances between 5 x diameter and 10 x diameter |
---|
Edge distance | 80 | 100 | 120 | 140 | 160 |
M16 anchors in tension | 0.70 | 0.78 | 0.87 | 0.96 | 1.00 |
M16 anchors in shear | 0.32 | 0.52 | 0.71 | 0.90 | 1.00 |
Reduction Factors for Edge distances between 5 x diameter and 10 x diameter |
---|
Edge distance | 100 | 120 | 140 | 160 | 180 | 200 |
M20 anchors in tension | 0.75 | 0.82 | 0.89 | 0.92 | 0.96 | 1.00 |
M20 anchors in shear | 0.32 | 0.52 | 0.71 | 0.80 | 0.90 | 1.00 |
Factors for Space reduction in Tension |
Space (mm) | 80 | 110 | 140 | 170 | 210 | 240 |
M16 anchors | 0.75 | 0.80 | 0.85 | 0.90 | 0.95 | 1.00 |
Space (mm) | 100 | 150 | 200 | 250 | 300 | 340 |
M20 anchors | 0.70 | 0.76 | 0.82 | 0.88 | 0.94 | 1.00 |
Increasing factors for cracked and non-cracked concrete |
| M16 | M20 |
C30/37 | 1.22 | 1.22 |
C40/50 | 1.41 | 1.41 |
C50/60 | 1.55 | 1.55 |